High power boiler for burning eco-pea coal - 5th class
To download
Feeder boiler Q MAX EKO GL – automatic medium power coal boiler. The structure is based on the Heiztechnik flame exchanger. It is equipped with a cast iron retort burner with an integrated worm fuel feeder.It can be equipped with 1 or 2 independent burners. The combustion process is controlled by weather-compensated automatics.
The boiler is equipped with a cast iron retort burner with an integrated worm fuel feeder. The boiler can be equipped with one or two independent burners together with controllers (depending on the boiler power). The boiler features high efficiency and may be operated in very simple manner.
As standard, the boiler is equipped with HT-tronic® 750 weather-compensated control unit with a colour display for intuitive operation of the device with the operation of boiler, central heating, mixing valve and DHW pump, with an optional connection of room thermostat and valve thermostat.
The automatics can be retrofitted with additional MZ-2 modules working in a network with the boiler or independently. The controller allows an Internet module to be mounted. The automatic controls keep return temperature stable by controlling the boiler pump. The boiler can be equipped with systems for automatic ash removal and pneumatic cleaning of the exchanger.
The boilers meet the environmental requirements of class 5 set out in the PN-EN 303-5:2012 standard. The 480 kW boiler meets the ECO DESIGN requirements according to EU Regulation 2015/1189. The boilers are certified by the “Polskie Ciepło” programme.
Rated power | kW | 80 | 100 | 120 | 150 | 200 | 240 | 300 | 350 | 400 | 480 |
Power range | kW | 24-80 | 33-100 | 36-120 | 45-150 | 60-200 | 72-240 | 90-300 | 105-350 | 120-400 | 144-480 |
Max. working temperature | oC | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 85 |
Water capacity | L | 640 | 680 | 720 | 920 | 1200 | 1400 | 1600 | 1900 | 2150 | 2600 |
Maximum operating pressure | Bar | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Minimum flue draught | Pa | 26 | 28 | 33 | 33 | 34 | 36 | 38 | 40 | 42 | 48 |
Technological connection | “ | 2 1/2 | 2 1/2 | 2 1/2 | 3 | 3 | 3 | 3 | Dn100 | Dn100 | Dn100 |
Flue connection | mm | 200 | 200 | 200 | 250 | 300 | 300 | 300 | 350 | 400 | 400 |
Boiler weight | kg | 1380 | 1450 | 1600 | 2200 | 2700 | 3100 | 3350 | 4500 | 4900 | 5850 |
Number of furnaces | pcs | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 |
Hopper volume | m3 | 1 | 1 | 1 | 1 | 1+1 | 1+1 | 1+1 | 1+1 | 1+1 | 1+1 |
Width cpl. | cm | 174 | 174 | 174 | 174 | 216 | 216 | 216 | 250 | 250 | 250 |
Depth of body with high flue | cm | 145 | 170 | 198 | 238 | 238 | 268 | 288 | 282 | 302 | 342 |
Body height | cm | 192 | 192 | 192 | 192 | 214 | 214 | 214 | 229 | 229 | 239 |
Height to flue centre | cm | 164 | 164 | 164 | 164 | 183 | 183 | 183 | 198 | 198 | 208 |
Height of return spigot | cm | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 |
- Boiler pump
- CH pump
- DHW pump
- Mixing valve pump
- Mixing valve
- Weather-compensated control
- Thermostat
- Colour display
- Modulated boiler operation
- HT Logic
Automation extension modules
- Cascade automation,
- Independent automatic heating circuit,
- Valve module,
- Valve pump,
- Mixing valve,
- Weather-compensated control,
- Thermostat,
- Buffer pump,
- Circulation pump,
- Wired remote control panel with room thermostat,
- Wireless remote control panel with room thermostat,
- Room thermostat – wired,
- Room thermostat, wireless with weekly programme,
- Room thermostat with a weekly programme – directly with a wireless APP mobile application,
- Internet module – operated via a web browser and mobile application,
- iPell combustion optimiser with Lambda probe,